Item # Fluke-360, Leakage Current Clamp Meter



360 Fluke Leakage Clamp Meter

larger image
  • Measure leakage current with 1 µA resolution, for monitoring of insulation erosion
  • Measure to 60 A, for general installation needs
  • Perform tests without powering down the installation or disconnecting equipment
  • Advanced shielding ensures accurate results when measuring near other conductors
  • Easy-to-carry, pocket-sized clamp with 40 mm (1.5") jaw size
  • Handy “Display-Hold” button for capturing readings in hard-to-reach places
  • Auto power-off, with warning buzzer, saves battery life
  • Meets safety standard VDE0404-4 and VDE0702 for leakage current and differential current measurement of electrical appliances





Specifications

Ranges

3 ma, 30 mA, 30 A, 60 A

Resolution

0.001 mA, 0.01 mA, 0.01 A, 0.1 A

Accuracy

± 1% rdg ± 5d (≤ 50 A)

Accuracy (50/60 Hz)

± 5% rdg ± 5d (>50 A)

Frequency Range

15-150 Hz

Maximum Current

60 A rms

Digital Display

3200 count LCD

Bargraph Display

32 segment LCD

Measurement Cycle

2/sec. (digital display), 12 /sec. (bargraph display)

Range Switching

Auto-range

Environment

0-50°C, <80 % RH (non-condensing)

Temperature Coefficient

<0.05 % of range/°C (0-18°C & 28-50°C, <50 A)

Influence of External Magnetic Field

0.0005 % typical (on current value of adjacent cable)

Influence of Conductor Position

Within accuracy

Circuit Voltage

≤300 Vrms

Safety Standard

EN 61010-1, EN 61010-2-032. 300 V CAT II, Pollution Degree 2

Battery Type

3 V Lithium battery (CR2032)

Battery Life

Approx. 90 hours (continuous use)

Max. Conductor Diameter

1.57 in
40 mm

Dimensions

6.9 x 2.8 x 1 in
176 x 70 x 25 mm