Weschler Instruments – Manufacturer & distributor of measurement & control equipment
440.238.2550   /   800.557.0064   /   
analog meters, digital meters, transducers, signal conditioners, data loggers and test instrumentation
Home | About Us | What's New | Industries | Weschler Products | All Products | Meter Mod Center | Reference | Contact | Site
Search Catalog 
      GO   
 All Categories    API DIN Transmitters, Isolators & Alarms
Weschler Instruments is a manufacturer and distributor of electrical and electronic measurement equipment. Customers worldwide use our products in power plants, steel mills, chemical plants, paper mills and other industrial applications that require rugged, reliable and accurate instrumentation.
All Categories > Product by Manufacturer > Absolute Process Instruments (API) > API DIN Transmitters, Isolators & Alarms > View Items 
    Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites

API DIN Transmitters, Isolators & Alarms

Check up to five results to perform an action.

APD-4300sm

larger image
  • Wide Choice of Inputs: Volts AC/DC, Amps AC/DC, Process V/mA, Strain, Frequency, RTD, Potentiometer
  • Variable Brightness I/O Status LEDs
  • 1200V Isolation
  • Output Test Button
  • Lifetime Warranty





 DOWNLOADS 

 width= Catalog Page 081a - API DIN Transmitters & Alarms
(PDF, 136KB)

 width= API - Brochure
(PDF, 4555KB)

Request InformationCompare Items   Results Per Page : 
  Results 1 - 31 of 31 1 

Item #

Function

Selectable Range

Input Range

Output Range

APD 4380 Transmitter Field 47 switch selectable,
0-10 mVDC to 0-130 VDC,
±5 mVDC to ±65 VDC,
0-200 uADC to 0-50 mADC
18 switch selectable, 0-1 VDC to 0-10 VDC
±5 VDC to ±10 VDC (10mA max)
0-2 mADC to 0-20 mADC,
4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD HV-DC Transmitter Field 8 switch selectable, 0-100 VDC to 0-1200VDC
or custom to 2000VDC
18 switch selectable, 0-1 VDC to 0-10 VDC
±5 VDC to ±10 VDC (10mA max)
0-2 mADC to 0-20 mADC,
4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 6380 Transmitter Field 28 switch selectable: 0-40 mVAC to 0-300 VAC TRMS,
22 switch selectable: 0-4 mAAC to 0-200 mAAC TRMS
18 switch selectable, 0-1 VDC to 0-10 VDC
±5 VDC to ±10 VDC (10mA max)
0-2 mADC to 0-20 mADC,
4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 4008 Transmitter Field Any full-range potentiometer from
0-100ohm to 0-1Mohm,
55 switch selectable, 0-10% to 0-100%
18 switch selectable, 0-1 VDC to 0-10 VDC
±5 VDC to ±10 VDC (10mA max)
0-2 mADC to 0-20 mADC,
4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 7580 Transmitter Field 30 switch selectable, 0-100 Hz to
0-30 kHz,100 mVrms to 150Vrms
18 switch selectable, 0-1 VDC to 0-10 VDC
±5 VDC to ±10 VDC (10mA max)
0-2 mADC to 0-20 mADC,
4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 4059 Transmitter Field 13 switch selectable: 5 mV to 400 mV;
1-10 VDC exc. For 1-4 350ohm
bridge or strain gauge sensors, 120 mA max.
18 switch selectable, 0-1 VDC to 0-10 VDC
±5 VDC to ±10 VDC (10mA max)
0-2 mADC to 0-20 mADC,
4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 4300 Transmitter Factory 0-100 mVDC to 0-300 VDC,
±100 mVDC to ±10 VDC,
0-1 mADC to 0-900 mADC
0-1 VDC to 0-10 VDC
±1 VDC to ±10 VDC (10mA max)
0-1 mADC to 0-20 mADC,
4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 6010 Transmitter Factory 0-40 mVAC to 0-300 VAC TRMS,
0-1 mAAC to 0-1000 mAAC TRMS
0-1 VDC to 0-10 VDC
±1 VDC to ±10 VDC (10mA max)
0-1 mADC to 0-20 mADC,
4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 4001 Transmitter Factory RTD (10-2000ohm), or Thermistor (2k-20kohm),
(specify type, curve, °C or °F & range)
0-1 VDC to 0-10 VDC
±1 VDC to ±10 VDC (10mA max)
0-1 mADC to 0-20 mADC,
4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 7010 Transmitter Factory 0-25 Hz to 0-20 kHz,
100 mVrms to 150Vrms
0-1 VDC to 0-10 VDC
±1 VDC to ±10 VDC (10mA max)
0-1 mADC to 0-20 mADC,
4-20 mADC (20V compliance, 1000ohm at 20 mA)
APD 4930 DC to DC Signal Splitter
Isolater/Transmitter
N/A 0-10mv to 100V
±50mV to ±10V
0-1ma to 0-50ma
4-20mA
0-1V to 0-10V
±1V to ±10V
0-1mA to 20mA
4-20mA
APD 1080 Alarm Field 24 switch selectable, 0-50 mVDC to 0-10 VDC,
±5 VDC to ±10 VDC, 0-1 mADC to 0-20 mADC
2 DPST relays, 8A, 1 setpoint
APD 1090 Alarm Field 24 switch selectable, 0-50 mVDC to 0-10 VDC,
±5 VDC to ±10 VDC, 0-1 mADC to 0-20 mADC
2 DPST relays, 8A, 2 setpoint
APD 1000 Alarm Factory 0-100 mVDC to 0-300 VDC,
0-1 mADC to 0-20 mADC, 4-20 mADC
2 DPST relays, 8A, 1 HI setpoint
APD 1020 Alarm Factory 0-100 mVDC to 0-300 VDC,
0-1 mADC to 0-20 mADC, 4-20 mADC
2 DPST relays, 8A, 2 setpoints HI/LO
APD 1030 Alarm Factory 0-100 mVDC to 0-300 VDC,
0-1 mADC to 0-20 mADC, 4-20 mADC
2 DPST relays, 8A, 2 setpoints, band alarm
APD 1600 Alarm Factory 0-50 mVAC to 0-300 VAC,
0-1 mAAC to 0-1000 mAAC
2 DPST relays, 8A, 1 HI setpoint
APD 1620 Alarm Factory 0-50 mVAC to 0-300 VAC,
0-1 mAAC to 0-1000 mAAC
2 DPST relays, 8A, 2 setpoints HI/LO
APD 1630 Alarm Factory 0-50 mVAC to 0-300 VAC,
0-1 mAAC to 0-1000 mAAC
2 DPST relays, 8A, 2 setpoints, band alarm
APD 1400 Alarm Factory RTD (10-2000ohm), or Thermistor (2k-20kohm),
(specify type, curve, °C or °F & range)
2 DPST relays, 8A, 1 HI setpoint
APD 1420 Alarm Factory RTD (10-2000ohm), or Thermistor (2k-20kohm),
(specify type, curve, °C or °F & range)
2 DPST relays, 8A, 2 setpoints HI/LO
APD 1430 Alarm Factory RTD (10-2000ohm), or Thermistor (2k-20kohm),
(specify type, curve, °C or °F & range)
2 DPST relays, 8A, 2 setpoints, band alarm
APD 1800 Alarm Factory Any full-range potentiometer from
0-100ohm to 0-1Mohm
2 DPST relays, 8A, 1 HI setpoint
APD 1820 Alarm Factory Any full-range potentiometer from
0-100ohm to 0-1Mohm
2 DPST relays, 8A, 2 setpoints HI/LO
APD 1830 Alarm Factory Any full-range potentiometer from
0-100ohm to 0-1Mohm
2 DPST relays, 8A, 2 setpoints, band alarm
APD 1700 Alarm Factory 0-10 Hz to 0-20 kHz, 100 mVrms to 150Vrms 2 DPST relays, 8A, 1 HI setpoint
APD 1720 Alarm Factory 0-10 Hz to 0-20 kHz, 100 mVrms to 150Vrms 2 DPST relays, 8A, 2 setpoints HI/LO
APD 1730 Alarm Factory 0-10 Hz to 0-20 kHz, 100 mVrms to 150Vrms 2 DPST relays, 8A, 2 setpoints, band alarm
APD 1500 Alarm Factory 100ohm to 10kohm bridge, strain gauge, load cell:
5-2000 mv; 1-10VDC excitation, 30mA max<> Specify excitation voltage, mV range and mV/V
2 DPST relays, 8A, 1 HI setpoint
APD 1520 Alarm Factory 100ohm to 10kohm bridge, strain gauge, load cell:
5-2000 mv; 1-10VDC excitation, 30mA max<> Specify excitation voltage, mV range and mV/V
2 DPST relays, 8A, 2 setpoints HI/LO
APD 1530 Alarm Factory 100ohm to 10kohm bridge, strain gauge, load cell:
5-2000 mv; 1-10VDC excitation, 30mA max<> Specify excitation voltage, mV range and mV/V
2 DPST relays, 8A, 2 setpoints, band alarm
  Results 1 - 31 of 31 1