Weschler Instruments – Manufacturer & distributor of measurement & control equipment
440.238.2550   /   800.557.0064   /   
analog meters, digital meters, transducers, signal conditioners, data loggers and test instrumentation
Home | About Us | What's New | Industries | Weschler Products | All Products | Meter Mod Center | Reference | Contact | Site
Search Catalog 
      GO   
 All Categories    Action Instruments Plug-In Signal Conditioners, Isolators and Alarms
Weschler Instruments is a manufacturer and distributor of electrical and electronic measurement equipment. Customers worldwide use our products in power plants, steel mills, chemical plants, paper mills and other industrial applications that require rugged, reliable and accurate instrumentation.
All Categories > Product by Manufacturer > Action Instruments > Action Instruments Plug-In Signal Conditioners, Isolators and Alarms > View Items 
    Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites

Action Instruments Plug-In Signal Conditioners, Isolators and Alarms

Check up to five results to perform an action.

Action Instruments Plug-In Signal Conditioners, Isolators and Alarms

larger image




Request InformationCompare Items   Results Per Page : 
  Results 1 - 15 of 15 1 

Item #

Functions

Input

Input Span (Field Configurable)

Output (Field Configurable)

AP4380 Isolator Single DC Current
DC Volt
1 mA to 100 mA
10 mV to 100V
DC Current (0–1 mA, 4–20 mA)
DC Voltage (0–5V, 0–10V)
AP4390 Isolator Dual DC Current
DC Volt
1 mA to 100 mA
10 mV to 100V
DC Current (0–1 mA, 4–20 mA)
DC Voltage (0–5V, 0–10V)
AP4382 Isolator (Bipolar Output) DC Current
DC Volt
1 mA to 100 mA
10 mV to 100V
DC Voltage (±5V, ±10V)
AP1080 Limit Alarm Single DC Volt 10 mV to 200V Single Trip (DPDT, 5A)
AP1090 Limit Alarm Dual DC Current 1 mA to 100 mA Single/Dual Trip (2 SPDT, 5A)
AP4351 Isolator Thermocouple B: 500°C to 1820°C
E: -150°C to 1000°C
J: -200°C to 750°C
K: -200°C to 1370°C
R/S: 50°C to 1760°C
T: -150°C to 400°C
DC Current (0–1 mA, 4–20 mA)
DC Voltage (0–5V, 0–10V)
AP1280 Limit Alarm Single Thermocouple B: 500°C to 1820°C
E: -150°C to 1000°C
J: -200°C to 750°C
K: -200°C to 1370°C
R/S: 50°C to 1760°C
T: -150°C to 400°C
Single Trip (DPDT, 5A)
Single/Dual Trip (2 SPDT, 5A)
AP1290 Limit Alarm Dual Thermocouple B: 500°C to 1820°C
E: -150°C to 1000°C
J: -200°C to 750°C
K: -200°C to 1370°C
R/S: 50°C to 1760°C
T: -150°C to 400°C
Single Trip (DPDT, 5A)
Single/Dual Trip (2 SPDT, 5A)
AP4081 Conditioner Bridge 10 mV to ±200 mV DC Current (0–1 mA, 4–20 mA)
DC Voltage (0–5V, 0–10V)
AP6380 Conditioner AC Current
AC Voltage
10mA to 100 mA AC
5 mA to 100 mA AC
50 mV to 200 VAC
DC Current (0–1 mA, 4–20 mA)
DC Voltage (0–5V, 0–10V)
AP1690 Limit Alarm Single AC Current
AC Voltage
10mA to 100 mA AC
5 mA to 100 mA AC
50 mV to 200 VAC
Single/Dual Trip (2 SPDT, 5A)
AP7380 Conditioner Frequency 2 Hz to 10 kHz DC Current (0–1 mA, 4–20 mA)
DC Voltage (0–5V, 0–10V)
AP7500 Conditioner DC (Fixed Range) Specify: 4–20 mA, 0–10V, 1–5V, 0–5V, 0–10V, or 10–50 mA Frequency (0–9 ppm up to 0–10 kHz) TTL: 0/6V
AP7501 Conditioner DC (Fixed Range) Specify: 4–20 mA, 0–10V, 1–5V, 0–5V, 0–10V, or 10–50 mA Frequency (0–0.12 ppm up to 0–130 ppm) DPDT Relay: 5A Max
AP4003 Conditioner PotentioMeter (Wide Ranging) Specify: 0–100% pot 100ohm to 100ohm pots DC 0-20mA, 4–20 mA, 0–5V, 0–10V
  Results 1 - 15 of 15 1